WAVE Dataflow Water Sampling Products

dataflowFaceThe WAVE Dataflow technology is an innovative and cost-effective alternative to slow, grab sampling methods. This device can sample vast areas of water, such as oceans, lakes, and rivers, providing instant, simultaneous readouts of up to 26 parameters.

The WAVE Dataflow collects this data every 2 seconds while you travel at up to 35 knots (40 mph). GPS technology within the device ties each data sample to it’s coordinating geo-reference point so that you can easily map your information.

With 10 different product configurations to suit a wide range of applications and needs, this portable, self-contained water sampling unit will change the way you collect samples. It’s compact, rugged, and easy to mount to a variety of vessels or stationary platforms.

Learn more about each of our WAVE Dataflow devices, and see how we can help you make a leap forward in your work!

WAVE Dataflow 1000WQM: Basic Water Quality Monitoring

This device can sample and map large areas of water quickly and accurately, and is designed for those who need to routinely assess common parameters for basic information about a site’s water quality.

Basic Unit Sampling Measurements Optional Sampling Measurements
  • Conductivity
  • Salinity
  • TDS
  • Temperature
  • pH
  • Dissolved Oxygen
  • GPS Mapping Integration
  • PAR in Air
  • Air Temperature
  • ORP

Click here to view the full data sheet for the WAVE Dataflow 1000WQM.


WAVE Dataflow 1500WPM: Water Pollution Monitoring

This device can effectively monitor lakes, rivers, and large bodies of water and quickly and reliably locate sources of pollution.

Basic Unit Sampling Measurements Optional Sampling Measurements
  • Conductivity
  • Salinity
  • TDS
  • Temperature
  • pH
  • Dissolved Oxygen
  • Chlorophyll A
  • Turbidity
  • GPS Mapping Integration
  • fDOM (Fluorescent Dissolved Organic Matter)
  • Light Transmittance
  • PAR in Air
  • Air Temperature
  • ORP

Click here to view the full data sheet for the WAVE Dataflow 1500WPM.


WAVE Dataflow 2000PDM: Advanced Pollution Detection & Monitoring

With all the benefits of the water pollution monitoring device, this advanced version is designed to test for additional parameters, locating the most subtle pollutants quickly and accurately.

Basic Unit Sampling Measurements Optional Sampling Measurements
  • Conductivity
  • Salinity
  • TDS
  • Temperature
  • pH
  • Dissolved Oxygen
  • Turbidity
  • Chlorophyll A
  • Phycoerytherin Algal Pigments
  • PTSDA
  • fDOM (Fluorescent Dissolved Organic Matter)
  • Optical Brighteners (Measure of Wastewater)
  • Tryptophan (Measure of Wastewater)
  • Chloride
  • GPS Mapping Integration
  • Phycocyanin Algal Pigments
  • Light Transmittance
  • Nitrate
  • Ammonium
  • Sodium
  • PAR in Air
  • Air Temperature
  • ORP

Click here to view the full data sheet for the WAVE Dataflow 2000PDM.


WAVE Dataflow 2500PEM: Oil/Petrochemical Exploration & Monitoring

This device provides continuous sampling with ultra-high resolution mapping, which is particularly useful for documenting oil and/or petrochemical spills or leaks. These include offshore oil sites, refineries, coastal waterways, aged or abandoned infrastructure, and sites of catastrophic events.

Basic Unit Sampling Measurements Optional Sampling Measurements
  • Conductivity
  • Salinity
  • TDS
  • Temperature
  • pH
  • Dissolved Oxygen
  • Turbidity
  • Chlorophyll A
  • Long-Chain Hydrocarbons (Crude Oil)
  • Short0Chain Hydrocarbons (Refined Fuel & Petrochemical Products)
  • GPS Mapping Integration
  • Chlorophyll A
  • Light Transmittance
  • PAR in Air
  • Air Temperature
  • ORP

Click here to view the full data sheet for the WAVE Dataflow 2500PEM.


WAVE Dataflow 3000FWE: Freshwater Exploration/Brine Monitoring

With increasing global water shortages, the need for freshwater is at an all-time high. This device could transform a county overnight by locating freshwater plumes in the ocean.

Basic Unit Sampling Measurements Optional Sampling Measurements
  • Conductivity
  • Salinity
  • TDS
  • Temperature
  • pH
  • Dissolved Oxygen
  • Turbidity
  • fDOM (Fluorescent Dissolved Organic Matter)
  • GPS Mapping Integration
  • Chlorophyll A
  • Rhodamine Dye
  • Fluorescine Dye
  • Phycocyanin Algal Pigments
  • Light Transmittance
  • Nitrate
  • Ammonium
  • Sodium
  • PAR in Air
  • Air Temperature
  • ORP

Click here to view the full data sheet for the WAVE Dataflow 3000FWE.


WAVE Dataflow 3500PHR: Physics & Hydrodynamics Research

This device is designed for monitoring and modeling the movement and mixing of fresh and salt waters. With parameters that take into account the importance of sediments and the way they move, this device will change the face of research.

Basic Unit Sampling Measurements Optional Sampling Measurements
  • Conductivity
  • Salinity
  • TDS
  • Temperature
  • pH
  • Dissolved Oxygen
  • Turbidity
  • Fluorescein Dye
  • Rodamine Dye
  • GPS Mapping Integration
  • Chlorophyll A
  • fDom (Fluorescent Dissolved Organic Matter)
  • Light Transmittance
  • PAR in Air
  • Air Temperature
  • ORP

Click here to view the full data sheet for the WAVE Dataflow 3500PHR.


WAVE Dataflow 4000ES: Ecosystem Services

When monitoring an ecosystem, having easily available and extremely accurate data to work with is paramount. This device allows users to test a number of parameters to determine where best to focus attention and resources.

Basic Unit Sampling Measurements Optional Sampling Measurements
  • Conductivity
  • Salinity
  • TDS
  • Temperature
  • pH
  • Dissolved Oxygen
  • Turbidity
  • Chlorophyll A
  • fDOM (Fluorescent Dissolved Organic Matter)
  • Ammonium
  • Nitrate
  • GPS Mapping Integration
  • Chlorophyll A
  • Rhodamine Dye
  • Fluorescein Dye
  • Tryptophan
  • Light Transmittance
  • PAR in Air
  • Air Temperature
  • ORP

Click here to view the full data sheet for the WAVE Dataflow 4000ES.


WAVE Dataflow 4500ER: Ecosystem Research

This device makes ecosystem research quick, accurate, and efficient, measuring 15 parameters (plus an optional 5 more) simultaneously every 2 seconds at speeds of 35 knots (40 mph). By providing a large amount of data quickly, this model will make plotting information simpler than ever.

Basic Unit Sampling Measurements Optional Sampling Measurements
  • Conductivity
  • Salinity
  • TDS
  • Temperature
  • pH
  • Dissolved Oxygen
  • Turbidity
  • Chlorophyll A
  • fDOM (Fluorescent Dissolved Organic Matter)
  • Rhodamine Dye
  • Phycoerytherin Algal Pigments
  • Phycocyanin Algal Pigments
  • Optical Brighteners (Measure of Wastewater)
  • Tryptophan (Measure of Wastewater)
  • GPS Mapping Integration
  • Fluorescein Dye
  • Light Transmittance
  • PAR in Air
  • Air Temperature
  • ORP

Click here to view the full data sheet for the WAVE Dataflow 4500ER.


WAVE Dataflow 5000FRM: Best Practices Farming (Run-Off Monitoring); Aquaculture

By helping to determine the exact locations of pollution source areas, the data provided by this device will help individuals and agencies develop best management practices to control non-point pollution.

Basic Unit Sampling Measurements Optional Sampling Measurements
  • Conductivity
  • Salinity
  • TDS
  • Temperature
  • pH
  • Dissolved Oxygen
  • Turbidity
  • Ammonium
  • Nitrate
  • Sodium
  • Tryptophan (Measure of Wastewater)
  • Chloride
  • GPS Mapping Integration
  • Rhodamine Dye
  • Fluorscein Dye
  • Phycocyanin Algal Pigments
  • Phycoerytherin Algal Pigments
  • Light Transmittance
  • PAR in Air
  • Air Temperature
  • ORP

Click here to view the full data sheet for the WAVE Dataflow 5000FRM.


WAVE Dataflow 5500SBM

This wholesale version of the WAVE Dataflow is entirely customizable based on your needs. Contact us to learn more!

Basic Unit Sampling Measurements Optional Sampling Measurements
  • Conductivity
  • Salinity
  • TDS
  • Temperature
  • pH
  • Dissolved Oxygen
  • Turbidity
  • Phycoerytherin
  • fDOM (Fluorescent Dissolved Organic Matter)
  • Tryptophan (Measure of Wastewater)
  • GPS Mapping Integration
  • Chlorophyll A
  • Phycocyanin Algal Pigments
  • Phycoerytherin Algal Pigments
  • Optical Brighteners
  • PTSA
  • Light Transmittance
  • PAR in Air
  • Air Temperature
  • ORP

Click here to view the full data sheet for the WAVE Dataflow 5500SBM.


Optional Peripherals for WAVE Dataflow Devices

Each WAVE Dataflow can also be outfitted with the following optional peripherals:

  • Water Depth & Bathymetry
  • UW Video
  • Surface Video
  • Probe Carrying Case
  • Wireless Display
  • Calibration Kit

Contact us today, and explore a whole new world of sampling technology! 952.829.0731